Wall & Ceiling Finish
9.1
Ceiling Is Uneven
Acceptable Performance/Condition
Where an isolated sag, bulge or area of waviness appears and is not a structural
problem, the variation from the specified plane shall not exceed ±12
mm. Surface imperfections due to slight variations in levelness of joints or
trusses supporting ceiling board are beyond the builder’s control.
Warranty
One -Year Work and Materials
Undulations caused by normal shrinkage of materials due to drying after construction
are excluded from the warranty.
Action
Sags or waves in ceilings greater than the Acceptable performance shall be repaired.
Remarks
Even when installed according to the Building Code, it is not unusual to see
undulation in
drywalled ceilings due to joint finishing. This occurrence can be exaggerated
by particular or critical lighting conditions and glossy finishes. Spray-applied
textures and matte finishes minimize this condition.
Some undulations may also be caused by truss uplift and applying ceiling drywall
over major structural components such as beams. See section 9.5 Ceiling/Wall
Joint Separation Commonly Referred to as Truss Uplift.