Flooring

12.3

Pattern Of Finished Flooring Is Out Of Alignment With Adjacent Wall Surfaces

Acceptable Performance/Condition
Finished flooring shall be installed in general visual alignment with adjacent wall surfaces. Variation greater than 12.5 mm in 1,800 mm is not acceptable when visible in a room used for its intended purpose. Patterns at seams between adjoining pieces shall be aligned to within 3 mm.

Warranty
One -Year Work and Materials

Action
Finished flooring not meeting the acceptable condition shall be repaired.

Remarks
This does not apply to angled or curved walls or flooring not designed to be aligned. The method of repair will vary with the type of finished flooring installed.